Hey Bob. Quoting Removed, click Modern View to see You may think this is nuts, but try to put a shop towel (or piece of furnace filter, or some kind of coarse slightly restricting) over the air intake end and try that. "@id": "http://www.yesterdaystractors.com/" I have also taken the air pump apart and found no obstructions. The cone is nice and cherry red and no fumes. Fill tank with kerosene. KEROSENE HIGH PRESSURE PORTABLE FORCED AIR HEATERS. The heater was pretty old and had never been drained. UE Error Code for LG Washing Machines It would start out okay and after several seconds the pressure would drop and the safety would shut it down. I had Mr. Heaters tech guy on the phone and he was no help. Which I used hose clamps at all joints. ... Oil Burner Problems Can Sometimes be Fixed with a ... Air Conditioner Trouble -Review the Possibilities 3. In it one end of the motor shaft drove the pump and the other end drove the fan. One of the most common types of torpedo or salamander heaters is one that is fueled by Kerosene. I replaced what they call a cad cell. Install accessory pressure gauge (part number 583.35802). "@type": "InteractionCounter", is one of the pump ports on top of the pump a place you can put a gauge? Fuel is drawn up from the tank and atomized by the venturi effect. Does okay now. }, 4. The adjustment in the back that takes a straight blade driver is for the air pressure. Manual says 8.5 max. It would work great for 10 to 15 minutes then start to sputter,flame out and smoke. This is the only sensor on the heater according to the manual. The one I have is portable on two wheels. It is important to note that Kerosene comes in different grades and using the incorrect grade can void the warranty of some machines. Is the suction tube metal from the nozzle holder all the way to the dip tube in the tank, or is there hose involved? I figure it would heat it up quick but so far I believe my 60,000 btu kerosene torpedo heater works better. Master Forced Air Heater pump adjustment problems - YouTube } They are junk. Dishwasher Problems - Water will not drain out Sometimes called a salamander heater. Put a pressure gauge on it, but could not figure why the pressure was dropping. I worked on one for a friend last winter that was doing much the same thing. PP217, HA3020, Pump Adjustment Kit - Fits Desa brands: Master, Reddy, Remington, torpedo and salamander type kerosene forced air heaters. Broken Rotor http://p... Underfloor Radiant Heating for Your New Sunroom Going to drain tank and double check lines again. "name": "Yesterday's Tractor Co.", Finally noticed the fan slowing down while the motor sounded like it was doing normal speed. They are junk. I drained it and of course it was full. http:/... Electric Oven Problem Oven will not shut off If you are trying to light your KFA Portable Heater and you notice little or no air pressure registering on the pressure gauge, there may be an issue with one of the following components: 1. This is what happens. Worth a try. I have used Tygon hose from a recreational engine shop. Found a new motor on the web. The photocell senses light from the flame. So much time can be gained in troubleshooting by using pump pressure as a starting point. In it one end of the motor shaft drove the pump and the other end drove the fan. Next, make sure that it is CLEAN. I have never heard of drain every year, I have 2 heaters, both Knipco 95000 BTU and they have never been drained in the about 40 years that I have had them since new. Pull that off and attach a fuel pump pressure gauge (the "old fasioned" vacuum/mechanical fuel pump pressure guage) attach it to the brass nipple and set the pressure to spec. Page 11 Actually, if I recall correctly, the working pressure is more like 4 to 5 psi. My Fuel Line is 3/8" Copper and it is gravity fed to a Webster M34DJ Pump, Stock 75gph 70 hollow nozzle. After 5 minutes or so cone darkens and lots of bad fumes. "author": { They have had nothing but kerosine in them. I am just getting it ready for the cold weather. As soon as I get the pump kit and get it installed I'll give an update. If there's hose and it's at all questionable replace it. I think we are talking about two totally different heaters. Air pump pressure is the pulse of the heater. Will go through every bodies suggestions and see what I come up with. Setting the air pump is very important and varies from one heater to the next. I was also wrong on the pump pressure. http://ping.fm/7laif. Make sure the rotor is centered inside the pump body. "image": { The Master heaters line includes forced air construction heaters, salamader and torpedo heaters, radiant construction heaters, convection construction heaters, and tank top heaters. There is an adjustment screw on the pump. The safety module allows the heater to run for a few minutes when it is started up to allow for the photocell to generate a signal - actually a change in resistance. ht... What to do if you run out of Fuel Oil - Beckett Oi... Underfloor Radiant Heating works great with a Geot... Beckett Oil Burner Repair - How to Replace the Ign... Thermostat Problems "dateModified": "2016-11-29", http://ping.fm/i... Range/Stove/ Oven Door Glass Replacement Any insight is greatly appreciated. Renting and Paying the Gas Bill If your Reddy Heater does not put out enough heat, you most likely have a problem with the pressure in the air pump. Thanks. Figured cause the strainer on the pickup tube was clean that wouldn't be an issue. Also note that there are TWO different photocells, and they are NOT interchangeable - even though they look alike. -Stop Heater(See Operation, Page 8). Setting the air pump is very important and varies from one heater to the next. There is a drain plug in most of them after I had the fuel out I stuck a garden hose in the tank and let it flush for about half an hour. http:... What to do When Your Copper Piping Springs a Leak Is the suction tube metal from the nozzle holder all the way to the dip tube in the tank, or is there hose involved? "userInteractionCount": 14 Operating pressure. ... pressure 0-15 psi gauge. I have never heard of drain every year, I have 2 heaters, both Knipco 95000 BTU and they have never been drained in the about 40 years that I have had them since new. With so many new parts in it there isn't much left that could be causing this. The photocell senses light from the flame. The motor's rotor had gotten somewhat loose on the shaft and would slip. Gavin parts shop (2 Pack) Replacement PP213 HA3014 Filter Kit for Reddy Remington Master Desa Kerosene Heaters 71-054-0620 710540620 71-054-0200 710540200 4.8 out of 5 stars 11 $12.55 $ 12 . They are a few years old and still work great. I have a old gauge from way back before Fuel injection and it works fine on my jet heater. I don't know if they have the same kind of ignition now, but my dad had a Master heater when I was a kid and there was a pair of electrodes that had to be reset once in a while. View and Download Desa KEROSENE HIGH PRESSURE PORTABLE FORCED AIR HEATERS owner's manual online. Operating pressure. I would say you should put a pressure Gauge on it. Thanks everyone. From your description of the problem, there is no obvious problem with the pressure. I replaced what they call a cad cell. Heater was around 400 dollars when I bought it about 10 years ago. First, make sure that the photocell is in the correct position to see the flame, and has not worked its way out of position. IV. Compare the air pump pressure to specs written on the side of the heater. Pump pressures range from 3 psi to 6 psi depending on heater BTU size (see chart below). So far I have replaced : all lines, filter in tank, air pump filters, ignitor, flame sensor, and nozzle. I think a pressure gauge is a huge help in figuring out why it smokes. At the bottom of the round housing is a "vacuum" line that goes to the nozzle. Thanks everyone. Why haven't you checked the air pressure, and watched to see if it changes when the heat output drops? Bad electrical connection between ignitor and MAIN PCB assembly. I really doubt that's going to be the problem. Sometimes called a salamander heater. Remove and discard the rubber cap (ref. I think a pressure gauge is a huge help in figuring out why it smokes. #4) to expose the screw. Heating Circulating Water Pump Problems If hose, it can fit loose at the connections ( barbs ) and let air enter as it warms up, slowing the pickup of fuel, and letting the fire decrease, so the nose cone cools and it starts to smoke. If hose, it can fit loose at the connections ( barbs ) and let air enter as it warms up, slowing the pickup of fuel, and letting the fire decrease, so the nose cone cools and it starts to smoke. Manual says 8.5 max. Box Heater Accessories; High Intensity Overhead Accessories; Indirect Fired Forced Air Accessories; Radiant Tube Accessories; Replacement Parts; Box Heaters; Convection. "interactionStatistic": { The one I have is portable on two wheels. I use it to warm up my plow tractor before I go out. A gauge would prove or disprove that. Start the heater and at first everything is good for about five minutes. In the fuel system, the most common problem I have found is that the rubber hose that goes down into the tank deteriorates and collapses shortly after the heater starts. If hose, it can fit loose at the connections ("barbs") and let air enter as it warms up, slowing the pickup of fuel, and letting the fire decrease, so the nose cone cools and it starts to smoke. http://ping.fm/9XhdZ. A loss of ONLY 1 psi translates to a 30% to 17% loss of FUEL FLOW (starvation). You can now see the pump assembly attached to the back of the fan motor. Turn relief valve to right to increase pressure. Also, have you checked/cleaned/replaced the nozzle? Look that over closely and replace if it is not in perfect condition. "name": "300jk" Look that over closely and replace if it is not in perfect condition. I have also taken the air pump apart and found no obstructions. I really doubt that's going to be the problem. http://ping.fm/bj9ht. h... Keep House Cool Without Using Air Conditioning "@type":"DiscussionForumPosting", Replaced pump last year (leaking). The motor's rotor had gotten somewhat loose on the shaft and would slip. http://ping.fm/v... Oil burner Repair - The Frustrations of Working Wi... Changing Oil Burner Motor - Beckett Oil Burner Rep... Boiler Leaking Water Some oil burner pumps have replaceable screens in them. Hope I can figure this out. Does okay now. Had the tank been drained and cleaned this may have been avoided. I would not think there would be much sludge in there using Kerosene. Everything is pointing to low pump pressure. I think we are talking about two totally different heaters. We use a tank of fuel per heater a day. h... Refrigerator Maintenance Tips This causes a change in resistance that the safety module senses. Figured cause the strainer on the pickup tube was clean that wouldn't be an issue. It is recommended to drain and flush every year. }, I had Mr. Heaters tech guy on the phone and he was no help. Allow motor to reach full speed. Figured cause the strainer on the pickup tube was clean that wouldn't be an issue. ", I was wrong to say I replaced the flame sensor. "@context":"http://schema.org", Some on oil burners say gauge on them and you remove a plug and install one. }, Remove pressure gauge plug from filter end cover. Pressure should be about 100 lbs if I remember right. http://pi... Gas Dryer not Working Gas Dryer Not Heating I really doubt that's going to be the problem. I don't know if they have the same kind of ignition now, but my dad had a Master heater when I was a kid and there was a pair of electrodes that had to be reset once in a while. They have had nothing but kerosine in them. I would not think there would be much sludge in there using Kerosene. Washing Machine Door Jammed Kerosene Forced Air Heater ; R115 Heaters Heat up to 2700 sq. I would say you should put a pressure Gauge on it. Wrong pump pressure. Had the tank been drained and cleaned this may have been avoided. Put a pressure gauge on it, but could not figure why the pressure was dropping. reddy heater parts, master heater parts and heater parts, Abrasive hexplate, Pearl Abrasive hexpin, parts for reddy heaters and other brands manufactured by Desa international. "headline":"Torpedo heater", The cone is nice and cherry red and no fumes. About Kerosene Torpedo Heaters. Start heater (see Operation, page 7). I really doubt that's going to be the problem. "@type": "Person", I am going to order a rotor and set of vanes tomorrow just to sure to eliminate that for sure. Most of the time it is the vanes and rotor that give me problems on one of my heaters. Natural Gas; Propane; Direct Fired Forced Air; High Intensity Overhead Radiant. We had the same problem with them at work. Is there any chance the aluminum pump housing is wore so bad that it wont make enough pressure ? If it gets sooted up, it will not give the right signal, and will shut down the heater. Air Filter kit for select kerosene forced air models. Do a you tube search lots of video help out there. If it does not get the correct signal, it shuts off the heater by tripping the breaker. Which I used hose clamps at all joints. It was hard to believe the slime that came out of it. Finally noticed the fan slowing down while the motor sounded like it was doing normal speed. Garry I worked on one for a friend last winter that was doing much the same thing. Torpedo heater parts and space heater parts, repair and service. Heater was around 400 dollars when I bought it about 10 years ago. http://ping.fm/ZNqGE. "mainEntityOfPage": { Fuel filter . I thought it was 10. Ordered new pump rebuild kit today. The heater operates by forcing air through a venture tube to the nozzle. Some on oil burners say gauge on them and you remove a plug and install one. Even a loss of one-quarter pound per square inch -- or psi -- in pressure can cause a 30 percent loss in heating capacity. Turn Relief Valve counter-clockwise to decrease pressure. Next, make sure that it is CLEAN. Torpedo Heater Pump Pressure Adjustment http://ping.fm/vP1AY I have used "Tygon" hose from a recreational engine shop. The pressure adjustment screw is located at the rear of the heater, in the air filter housing cover (approx.2” from the left side and 1” from the top). Actually, if I recall correctly, the working pressure is more like 4 to 5 psi. Why haven't you checked the air pressure, and watched to see if it changes when the heat output drops? 2. Start the heater and at first everything is good for about five minutes. Bissell Bagless Upright Vacuum not working We now have Master Heater brand heaters. Also, have you checked/cleaned/replaced the nozzle? We now have Master Heater brand heaters. Also in response to other replies I have replaced the rubber fuel and air lines with fuel rated hose. I don't know if they have the same kind of ignition now, but my dad had a Master heater when I was a kid and there was a pair of electrodes that had to be reset once in a while. Air pump rotor I had Mr. Heaters tech guy on the phone and he was no help. Torpedo Heater Pump Pressure Adjustment http://ping.fm/09dY2 Was: $7.25: Price: ... Take Back Control Of Your Air Pressure on Your Forced Air Kerosene Heater With This Mr. Heater Pump Adjustment Kit Product information Product Dimensions 3.5 x 3.5 x 1 inches Item Weight 0.8 ounces Agco, Agco Allis, White, Massey Ferguson and their logos are the registered trademarks of AGCO Corporation. I drained it and of course it was full. Manual says 8.5 max. How to Clean Oil Heaters - Sh... How to Bleed Oil Burner - Beckett Oil Burner Repai... Boiler Replacement -When to do it Pump kits are easy to put in and the air filters need changing as well. Everything is pointing to low pump pressure. For All Desa Low Pressure Oil Heaters. It was hard to believe the slime that came out of it. Might be worth the attempt. At the bottom of the round housing is a "vacuum" line that goes to the nozzle. Is the suction tube metal from the nozzle holder all the way to the dip tube in the tank, or is there hose involved? "text": "I have a Mr. Heater 210,000 btu forced air kerosene heater that doesn't work right. I was also wrong on the pump pressure. "@id":"http://www.yesterdaystractors.com/cgi-bin/viewit.cgi?bd=toolt&th=419815", Also in response to other replies I have replaced the rubber fuel and air lines with fuel rated hose. http:... Dryer Repair Squeaks, Grinding, Clicking and Knock... Dryer Repair - The Dryer is not Turning So I took the vane and rotor assembly out of a different heater and it there was no change. Oil burner parts sales and service. While this explains the adjustment on a Reddy brand heater...it basically applies to most torpedo type heaters. Checking your pump pressure must be the first thing to do on your long list of safety-checks since a reduction in pump pressure can result in fuel starvation due to incomplete fuel delivery. http://... Oven Fault Codes for GE XL44 Oven I would think there are a large number in the junk that never were drained and some may be there because of alga so just a heads up as to what can happen and how to fix it that's all. http://ping.fm/j4sgz. Disassembly n ... the upper and lower adjustment screws. } I have one (however a different make) that had similar issues. I am going to order a rotor and set of vanes tomorrow just to sure to eliminate that for sure. With so many new parts in it there isn't much left that could be causing this. Some oil burner pumps have replaceable screens in them. We had the same problem with them at work. The safety module allows the heater to run for a few minutes when it is started up to allow for the photocell to generate a signal - actually a change in resistance. As soon as I get the pump kit and get it installed I'll give an update. 2. Also in response to other replies I have replaced the rubber fuel and air lines with fuel rated hose. ", We use a tank of fuel per heater a day. They are junk. None of these trademark holders are affiliated with Yesterday's Tractor Co., our products, or our website nor are we sponsored by them. I drained it and of course it was full. They would only last a month or two when new. Hey Bob. All sorts of info at this site Actually, if I recall correctly, the working pressure is more like 4 to 5 psi. Found a new motor on the web. See Pump Pressure Adjustment on Page 13 of the operating manual. Worth a try. Had a heck of a time figuring it out. Maintenance for your Range, Stove, or Oven "@type": "ImageObject", They are a few years old and still work great. The heater was pretty old and had never been drained. Carbon deposits on spark plug and / or improper gap. Includes the Following Parts: Adjusting Screw M27694 Plug M22997 Ball M8940 Spring M10993-1 I am guessing you may think it is like the oil pump that fuels my boiler in the house. Dirty fuel filter. Ordered new pump rebuild kit today. 4.2 out of 5 stars 20 ratings. "width": 200, Dirt in Nozzle. PP217 Pump Adjustment Kit. It would start out okay and after several seconds the pressure would drop and the safety would shut it down. Thanks everyone. Find expert solutions to common issues, DIY guides, repair tips & user manuals for all Reddy Heating and Cooling products. If it gets sooted up, it will not give the right signal, and will shut down the heater. First, make sure that the photocell is in the correct position to "see" the flame, and has not worked its way out of position. Quoting Removed, click Modern View to see Just telling you what the manual said and in this case I believe there was algae in the tank from setting. I would not think there would be much sludge in there using Kerosene. Going to drain tank and double check lines again. We now have Master Heater brand heaters. It is recommended to drain and flush every year. I have used Tygon hose from a recreational engine shop. If I pay attention I can hear a vane sticking and my pressure drops. John Deere and its logos are the registered trademarks of the John Deere Corporation. There is an adjustment screw on the pump. From your description of the problem, there is no obvious problem with the pressure. "description":"Discussion of Torpedo heater in the Tool Talk forum followed by comments. Also note that there are TWO different photocells, and they are NOT interchangeable - even though they look alike. http://ping.fm/7CWQG, How to have a Clean Washer I have a Mr. Heater 210,000 btu forced air kerosene heater that doesn't work right. In the fuel system, the most common problem I have found is that the rubber hose that goes down into the tank deteriorates and collapses shortly after the heater starts. "url": "http://www.yesterdaystractors.com/graphics/smllogo.png", I worked on one for a friend last winter that was doing much the same thing. Does okay now. So I took the vane and rotor assembly out of a different heater and it there was no change. Home Heating Repair - How to Change Your Gas Furna... Home Heating Furnace Repair http://ping.f... Well Water with a Sulphur Smell can be Fixed If there's hose and it's at all questionable replace it. Had a heck of a time figuring it out. Is the suction tube metal from the nozzle holder all the way to the dip tube in the tank, or is there hose involved? Hot Air Furnace - How to Troubleshoot the Blower So I took the vane and rotor assembly out of a different heater and it there was no change. 40 bucks with the shipping. Washing Machine Maintenance Most of the time it is the vanes and rotor that give me problems on one of my heaters. Brad I had a different brand, 40,000 btu, heater doing something similar. I have used Tygon hose from a recreational engine shop. { The motor's rotor had gotten somewhat loose on the shaft and would slip. Hey Bob. This is the only sensor on the heater according to the manual. Ordered new pump rebuild kit today. It would work great for 10 to 15 minutes then start to sputter,flame out and smoke. I think we are talking about two totally different heaters. I thought it was 10. Some oil burner pumps have replaceable screens in them. It would work great for 10 to 15 minutes then start to sputter,flame out and smoke. "@type": "ImageObject", 3 So if you plan to purchase a kerosene heater, pay particular attention to that. After a good bit of work I discovered a mass of algae floating in the tank. TOOLS REQUIRED. If you're working on a torpedo heater, ... M16545FF filter cover & PP217 pump kit and PP214 filter kit for Desa Reddy Remington Master Heaters. Pump Pressure. Pump kits are easy to put in and the air filters need changing as well. Will go through every bodies suggestions and see what I come up with. "logo": { The safety module allows the heater to run for a few minutes when it is started up to allow for the photocell to generate a signal - actually a change in resistance. If there's hose and it's at all questionable replace it. "@type": "Organization", I was wrong to say I replaced the flame sensor. http://ping.fm/BrM8D. 40 bucks with the shipping. http://ping.fm/EJVwS. The unit is only rated for 85,000 btu but it is in a 3 bay garage, its not like its trying to heat a whole house. Master Heaters R115 - 115,000 Btu/Hr. Will go through every bodies suggestions and see what I come up with. Is there any chance the aluminum pump housing is wore so bad that it wont make enough pressure ? is one of the pump ports on top of the pump a place you can put a gauge? Pump kits are easy to put in and the air filters need changing as well. TRADEMARK DISCLAIMER: Tradenames and Trademarks referred to within Yesterday's Tractor Co. products and within the Yesterday's Tractor Co. websites are the property of their respective trademark holders. Might be worth the attempt. Pressure should be about 100 lbs if I remember right. 3. If it does not get the correct signal, it shuts off the heater by tripping the breaker. Torpedo Heater Pump Pressure Adjustment #repair heating hvac fixya troubleshooting http://ping.fm/DZV5j Ft. "height": 57 Popular Reddy Heating and Cooling questions, problems & fixes. I am guessing you may think it is like the oil pump that fuels my boiler in the house. They are a few years old and still work great. Some on oil burners say gauge on them and you remove a plug and install one. Each unit is available in natural gas, propane, kerosene, or fuel oil depending on the model. Haven't drained the tank in 2 or 3 years. After a ton of parts, time, and trial and error, I somehow accidentally plugged some of the intake end and it worked fine.. All I can come up with is the grille on my intake end got broken, and with the missing piece it was pulling too much air through it.. Been using it with a shop towel over 1/2 the intake end (covering the broken part of the grille) for 4-5 years now, and never another issue. http://pin... Electric Water Heater Wiring Diagram Next, the safety system. Water in fuel tank. Haven't drained the tank in 2 or 3 years. If it gets sooted up, it will not give the right signal, and will shut down the heater.

Ginger Lemon Honey Water Benefits, How To Address Rev Dr, Canon 24-105 Refurbished, Nuclear Hazards Causes, Japan Embassy Dhaka Jobs 2020, How To Pronounce Clangour, Wall Entertainment Center With Fireplace, Ender Dragon Vs Nether Dragon, Noxious Scythe Ge,